Home Technique & Service Products Projects Certificates Contact Us

EL Lighting

EL Wire

Electroluminescent Wire

Inverter for EL wire

EL Wire Gifts & Toys

Accessory-Connector

Use Guide

EL Panel

EL Tape

EL Backlight

EL T-Shirt

EL Car Sticker

EL/LED Poster

LED Lighting

LED Module

LED Strip

Chasing Light

Flexible Series

Rigid Aluminum Light

LED Bulb

LED Tube

LED Emergency and Portable Tube

LED RGB Color Tube

Split Style LED Tube

Integrated LED Tube

PIR + Sensor LED Tube

Dimming LED Tube

Waterproof LED Tube

LED Neon

LED Controller

Wifi controller series

Common controller series

Dimmer series

IR controller series

RF controller series

Dream-color controller series

DMX controller series

SD card controller series

DALI contoller series

Solar controller series

Touch panel controller series

LED Spot Light

LED Floodlight

LED Down Light

LED Panel Light

LED Power Supply

Plastic Case Power Supply

Mean Well Power Supply

Metal Shell Power Supply

Tabletop Power Supply

Wall Mounted Power Supply

Waterproof Power Supply

Battery Charger Power Supply

LED Under Cabinet Light

Accessory-Connector

LED Holiday Decoration Light

Fiberglass Statue

LED Landscape Tree

LED String/Icicle/Curtain/Waterfall/Net Light

2D Street Motif

3D Sculpture/Motif

Home > Products > LED Lighting ï¹¥ LED Controller ï¹¥ DALI contoller series

DALI Group Control Panel

Place of Origin China
Brand Name Okled
Model Number LN-TRF-DALIMODULE-GC
Correlated Color Temperature 0-50℃
Inquiry

Detailed Product Description

                      Product Specifications

  

NAME: DALI Group Control Panel

MODEL: LN-TRF-DALIMODULE-GC

 

3.jpg 

 

Summarization

DALI (Digital Addressable Lighting Interface) is an international standard, popular lighting control protocol, with digital addressing dimming, stable, various dimming ways, easy to install, compatible with many big factories such characteristic.

DALI touch group control panel adopt advanced computer control chip, can group switch, dimming and programme of dimmer on bus, also can use button without computer to operate, it is convenience for user.

 

 

 

Technical parameters

l Supply voltage: DALI bus signal

l Working temperature: 0-50°C

l Storage temperature: -25-55°C

l Input signal: 4 channel physics switch signal

l Output signal: standard IEC60929 DALI signal

l Quiescent current: < 6MA

l External dimension: L86 * W86 * H36mm

l Gross weight: 63.8g

l Net weight: 34.9g


 

External Dimension: 

 

4.jpg 

 

 

 

 

Interface Specifications:

 

5.jpg          

 

 

 

 

Group control panel function

DALI touch group control panel can operate 1-2 group or equipments on broadcast bus, can control equipments on/off and brightness on bus, and the controller can control groups range is 16 groups.

 

 Button duration

Function

single key

Up key longest time

DOWN key longest time

10-500ms

 

 

ON at 100% or OFF

 

10-500ms

 

ON at Max or OFF

 

 

10-500ms

ON at Min or OFF

>500ms

>500ms

>500ms

ON (if required) and level adjust 

 


 

Group programme operate instruction

 

Enter group programme mode

Below table are enter the program mode operating steps, operating key is any key which connect the

panel. And if you do not run continuously according the operating steps, it will exit program mode.

Order

System response

Long press one button for 10s

Buzzer rang one sound

Release one button for 1s

Buzzer rang one sound again

Press this button again for 1s

Buzzer rang two sound

After release button, hear a sound again

System finish distribute address, enter to group programme mode

 

    The module which enter the programme mode group, have 2 kinds of programme way, the selected DALI dimmer "add group" and "delete group".

 

Choose dimmer

    To make the DALI dimmer module to join delete group, first need to make the DALI dimmer which wants to be programmed in the selected sate. Press the button less than 500ms, it will select the DALI dimmer one by one, each equipment will be selected alternate.

 

Selected DALI dimmer "add group"

    After choose the equipment, press the button, it will hear 2 buzzer rang sound, and then release the button, it can make the selected DALI dimmer add to button represents group.

 

Selected DALI dimmer "delete group"

After choose the equipment, press the button, it will hear 3 buzzer rang sound, and then release the button, it can make the selected DALI dimmer remove to button represents group.

 

Log out group programme mode

Under the programme mode, long press the button, after hear the fourth buzzer, then release, can hear continuous three sound, that prove the dimming module have quit the programme mode already. 

 

Set button operate represents group value

DALI touch group control panel can choose broadcast or 1-2 in 16 groups to operate, choose way as the list below: 

Group Selector

Position rotating switch

First input 

Group address

Second input 

Group address

0

Broadcast

1

1

1

2

2

2

3

3…9

3…9

4…10

A…F

10…15

11…16


 

 

 

Typical Application

DALI touch group control panel connect on DALI bus directly, panel take power from bus 

directly (quiescent current 5-7MA).

 